Safety, Reliability, Compatibility, Efficiency
SSE-HL8~15K-P2SA
The 8~15kW split-phase energy storage inverter, versatile power for diverse Needs. It's designed for for homes, villas, and small commercial applications. Enjoy flexible operation with multiple modes, U.S. standard compliance (UL 1741, UL 1547, FCC Part 15B, UL 1998, etc.), and durable NEMA 4X protection.
This diagram shows the 8~15kW split-phase inverter system: DC power from the battery, PV array, and diesel generator goes through safety fuses and relays, a DC isolation switch, and capacitors. The inverter then converts DC to AC, which is filtered and stabilized, before outputting clean AC power to the grid and loads.
Other Applications:
· AC Coupling with existed solar system
· Off-grid and back-up applications
· On-grid solar system without battery (SupportEPs even without battery)
· Off-grid and back-up applications
· Single and three phase paralleling system
· Energy storage system with peak shaving Function
Related Parameters
| TECHNICAL SPECIFICATION | ||||
| Model |
SSE-HL8K-P2SA / SSE-HL8K-P2SA-S |
SSE-HL10K-P2SA / SSE-HL10K-P2SA-S |
SSE-HL12K-P2SA / SSE-HL12K-P2SA-S |
SSE-HL15K-P2SA / SSE-HL15K-P2SA-S |
| INVERTER INPUT / OUTPUT (GRID) | ||||
| Rated Power | 8 kW | 10 kW | 12 kW | 15 kW |
|
Rated Voltage
|
120 V a.c. / 240 V a.c. (Split Phase), 280 V a.c. (2 / 3 Phase) | |||
|
Rated Frequency
|
60 Hz | |||
|
Power Factor Range
|
0.8 leading~0.8 lagging
|
|||
|
Switch Time
|
<10 ms | |||
|
Max. Input Current
|
50 A a.c. | 62.5 A a.c. | ||
|
Max. Output Current
|
33.4 A a.c. | 41.7 A a.c. | 50 A a.c. | 62.5 A a.c. |
|
Max Output Overcurrent Protection
|
250 V a.c. / 125 A a.c
|
|||
|
GEN Rated Power
|
8kW | 10kW | 12kW | 15kW |
| BATTERY | ||||
|
Battery Type
|
Lithium / Lead-acid
|
|||
|
Battery Voltage Range
|
40~60 V d.c. | |||
|
Rated Battery Voltage
|
51.2 V d.c. | |||
|
Max. Charge Current
|
167 A d.c. | 210 A d.c. | 250 A d.c. | 275 A d.c. |
|
Max Discharge Current
|
167 A d.c. | 210 A d.c. | 250 A d.c. | 275 A d.c. |
|
Reverse Connect Protection
|
Yes | |||
|
PV INPUT
|
||||
|
No. of MPPT Tracker / Strings
|
3 / 2+2+2 | 3 / 2+2+2 | 3 / 2+2+2 | 3 / 2+2+2 |
|
Max. PV Array Power
|
12 kW | 15 kW | 18 kW | 22.5 kW |
|
Max. DC Voltage
|
550 V d.c. | |||
|
MPPT Voltage Range
|
100~500 V d.c. | |||
|
Start-up Voltage
|
120 V d.c. | |||
|
Max. Input Current
|
26+26+26 A d.c. | |||
|
Isc PV (Absolute Maximum)
|
39 A d.c. | |||
|
AC OUTPUT (EPS)
|
||||
|
EPS Rated Output Voltage
|
120 V a.c. / 240 V a.c. (Split Phase), 208 V a.c. (2 /3 Phase)
|
|||
|
EPS Rated Output Frequency
|
60 Hz | |||
|
EPS Rated Output Active Power
|
8 kW | 10 kW | 12 kW | 15 kW |
|
EPS Rated Output Apparent Power
|
8 kVA | 10 kVA | 12 kVA | 15 kVA |
|
EPS Rated Output Current
|
33.4 A a.c. | 41.7 A a.c. | 50 A a.c. | 62.5 A a.c. |
|
Overload Capacity (Off Grid)
|
200% 10s | |||
|
EFFICIENCY
|
||||
|
MPPT Efficiency
|
99.50% | |||
|
California-eficiency
|
96.50% | |||
|
Max. Eficiency
|
97.50% | |||
|
PROTECTION & FEATURE
|
||||
|
Insulation Monitoring
|
Yes | |||
|
Residual Current Monitoring
|
Yes | |||
|
Parallel Function
|
Yes | |||
|
Protection Degree
|
NEMA 4X | |||
|
Certifications
|
UL 1741, FCC Part 15B, UL 1547, UL 1699B, HECO SRD 2.0, CEC efficiency | |||
|
Other Protection
|
Overload, Over temperature, Short circuit, Anti-islanding
|
|||
|
GENERAL PARAMETER
|
||||
|
Storage Temperature
|
-25℃~+60℃ (-13℉~+140℉) | |||
|
Operating Temperature
|
-25℃~+60℃ (-13℉~+140℉), >45℃ (+113℉) Derating to 60% | |||
|
Humidity
|
0~95% (Non-condensing) | |||
|
Operating Altitude
|
4000 m (>2000 Derating) | |||
|
Noise
|
<45 dB | |||
|
Machine Dimensions (W*H*D)
|
466*756*242 mm (18.35*29.76*9.35 inch) | |||
|
Machine Weight / N.W.
|
45 kg (99.21 lbs) | |||
|
DISPLAY & COMMUNICATION
|
||||
|
Display
|
App+LED / LCD (-S version) | |||
|
Interface
|
RS485 / WiFi / CAN (Optional: Bluetooth / LAN / 4G / Meter)) | |||
|
||||
Application Scenario