The power cuts out without warning. Your fridge stops, the router blinks off. This inverter switches to backup in under 10 milliseconds and absorbs load spikes up to 150 percent, so the outage never really happens. Life just continues.
Add an EV charger or heat pump later, and most systems fall short. With 1.5 times PV oversizing and dual MPPTs across four strings, this inverter keeps up as your home grows, so today's choice still makes sense years from now.
High-capacity batteries need an inverter that can actually keep up. With up to 200A charge and discharge capability, the SSE-HL6~10K-P1EU-SC gets your battery bank fully charged faster and delivers full power exactly when you need it.
|
TECHNICAL SPECIFICATION
|
|||
| Model | SSE-HL6K-P1EU-SC | SSE-HL8K-P1EU-SC | SSE-HL10K-P1EU-SC |
|
NVERTER INPUT/OUTPUT (GRID)
|
|||
|
Rated Power
|
6 kW | 8 kW | 10 kW |
|
Rated Voltage
|
220 / 230 / 240 V a.c., L+N+PE | ||
|
Rated Frequency
|
50 Hz / 60 Hz | ||
|
Power Factor Range
|
0.8 leading / 0.8 lagging | ||
|
Switch Time
|
<10 ms | ||
|
Current (Maximum Continuous)
|
26.1 A a.c. | 34.8 A a.c. | 43.5 A a.c. |
|
Max Output Overcurrent Protection
|
250 V a.c. / 100 A a.c. | ||
|
BATTERY
|
|||
|
Battery Type
|
Lithium / Lead-acid | ||
|
Battery Voltage Range
|
45 ~ 58 V d.c. | ||
|
Rated Battery Voltag
|
51.2 V d.c. | ||
|
Max. Charge Current
|
135 A d.c. | 180 A d.c. | 200 A d.c. |
|
Max. Discharge Current
|
135 A d.c. | 180 A d.c. | 200 A d.c. |
|
Reverse Connect Protection
|
Yes | ||
| PV INPUT | |||
|
No. of MPPT Tracker / Strings
|
2 / 2+2 | ||
|
Max. PV Array Power
|
9 kW | 12 kW | 15 kW |
|
Max. DC Voltage
|
550 V d.c. | ||
|
MPPT Voltage Range
|
120 ~ 500 V d.c. | ||
|
Start-up Voltage
|
120 V d.c. | ||
|
Max. Input Current
|
26 / 26 A d.c. | ||
|
Isc PV (Absolute Maximum)
|
34 / 34 A d.c. | ||
| AC OUTPUT (EPS) / GENERATOR | |||
|
EPS Rated Output Voltage
|
220 / 230 / 240 V a.c., L+N+PE | ||
|
EPS Rated Output Frequency
|
50 Hz / 60 Hz | ||
|
EPS Rated Output Active Power
|
6 kW | 8 kW | 10 kW |
|
EPS Rated Output Apparent Power
|
6 kVA | 8 kVA | 10 kVA |
|
EPS Rated Output Current
|
21.6 A d.c. | 34.8 A d.c. | 43.5 A d.c. |
|
Overload Capacity (Off Grid)
|
110%, 600s / 120%, 10s / 150%, 0.02s | ||
| EFFICIENCY | |||
|
MPPT Efficiency
|
99.20% | ||
|
Euro-efficiency
|
96.50% | ||
|
Max. Efficiency
|
97.00% | ||
| PROTECTION & FEATURE | |||
|
Insulation Monitoring
|
Yes | ||
|
Residual Current Monitoring
|
Yes | ||
|
Parallel Function
|
Yes | ||
|
Protection Degree
|
IP65 | ||
|
Other Protection
|
Over voltage, Over current, Over temperature, Short circuit, Active anti-islanding etc. | ||
| GENERAL PARAMETER | |||
|
Storage Temperature
|
-25°C~ +60°C | ||
|
Operating Temperature
|
-25°C ~ +60°C (Linely derating to 10% when exceed +45°C ~ +60°C) | ||
|
Humidity
|
0-95% (Non-condensing) | ||
|
Altitude
|
2000 m (>2,000 m Derating) | ||
|
Noise
|
<60 dB | ||
|
Warranty
|
5 year | ||
|
Machine Dimension(W*H*D)
|
361 * 545 * 222 mm | ||
|
Machine Weight / N.W.
|
25 kg | ||
| DISPALY & COMMUNICATION | |||
| Display | LCD + APP | ||
| Interface | RS485 / CAN / WiFi / Bluetooth | ||
|
|||