• Advanced SiC OSFET technology for higher efficiency and lightweight design.
• Fast switch time (<10ms) ensures seamless power.
• Wide MPPT voltage range: 150V-950V d.c max.1000V .
• Dual battery interfaces, supports 100A×2 for independent battery packs or 200A for parallel connections, providing flexibility.
• Supports black start, off-grid and economy mode for versatile power solutions.
• AC coupled to retrofit existing solar system.
Safety, Reliability, Compatibility, Efficiency
SSE-HH40K~60K-P3EU
40K~60KW | Three Phase | High Voltage | IP66
The SSE-HH40K~60K-P3EU hybrid inverter integrates local and remote EMS functions to support multiple power grid dispatch modes. The battery voltage ranges from 150V to 800V. It also supports up to 6 parallel machines, and supports SOC balancing function under parallel machines. It supports single-phase 100% unbalanced load operation under off-grid conditions, adapting to various load scenarios.
Enhanced Accessibility & Versatility
Application Scenario
Related Parameters
| TECHNICAL SPECIFICATION | |||
| Model | SSE-HH40K-P3EU | SSE-HH50K-P3EU | SSE-HH60K-P3EU |
| INVERTER INPUT/OUTPUT (GRID) | |||
| Rated Power (Input / Output) | 138 kW / 40 kW | 138kW / 50 kW | 138 kW / 60 kW |
| Rated Voltage | 380 / 400 V a.c., 3W+N+PE | ||
| Rated Frequency | 50 Hz / 60 Hz | ||
| Power Factor Range | 0.8 leading~ 0.8 lagging | ||
| Switch Time | <10 ms | ||
| Max. Continuous Current (Input / Output) | 200 A a.c. / 58 A a. c. | 200 A a. c. / 72 A a. c. | 200 A a. c / 87 A a. c. |
| Max. Output Overcurrent Protection | 123 A a. c. | 153 A a. c. | 185 A a. c. |
| BATTERY | |||
| Battery Type | Lithium / Lead-acid | ||
| Battery Voltage Range | 150 ~ 800 V d.c. | ||
| Rated Battery Voltage | 200 V d. c. | 250 V d. c. | 300 V d. c. |
| Max. Charge Current | 2*100 A d. c. | ||
| Max. Discharge Current | 2*100 A d. c | ||
| Reverse Connect Protection | Yes | ||
| PV INPUT | |||
| No. of MPPT Tracker/Strings | 4 / 2+2+2+2 | ||
| Max. PV Array Power | 68 kW | 85 kW | 100 kW |
| Max. DC Voltage | 1000 V d. c. | ||
| MPPT Voltage Range | 150 ~ 950 V d. c. | ||
| Start-up Voltage | 125 V d. c. | ||
| Max. Input Current | 8x20 A d. c. | ||
| Isc PV (Absolute Maximum) | 8x30 A d. c. | ||
| AC OUTPUT (EPS) | |||
| EPS Rated Output Voltage | 380 / 400 V a.c., 3W+N+PE | ||
| EPS Rated Output Frequency | 50 Hz / 60 Hz | ||
| EPS Rated Output Active Power | 40 kW | 50 kW | 60 kW |
| EPS Rated Output Apparent Power | 44 kVA | 55 kVA | 66 kVA |
| EPS Rated Output Current | 58 A a. c. | 72 A a. c. | 87 A a. c. |
| Overload Capacity (Off Grid) | 110% 30s / 120% 10s / 150% 0.2s | ||
| EFFICIENCY | |||
| MPPT Efficiency | 99.9% | ||
| Euro-efficiency | 97.5% | ||
| Max. Efficiency | 98.5% | ||
| PROTECTION & FEATURE | |||
| Insulation Monitoring | Yes | ||
| Residual Current Monitoring | Yes | ||
| Parallel Function | Yes, up to 6pcs | ||
| Protection Degree | IP66 | ||
| Certifications | CE10-21, EN 50549-1, VDE-AR-N 4105, UNE 217002, NTSTYPEA, G99, AS/NZS 4777.2 | ||
| Other Protection | Ground Fault Current Monitoring, Earth Fault Detection, Residual Current (RCD) Detection | ||
| GENERAL PARAMETER | |||
| Storage Temperature | -25℃ ~ +60℃ | ||
| Operating Temperature | -25℃ ~ +60℃ (>+45℃, Derating) | ||
| Humidity | 0% ~ 95% (Non-condensing) | ||
| Operating Altitude | 4,000 m (>2,000 m Derating) | ||
| Noise | <65 dB | ||
| Dimensions (W*H*D) | 544*880*278 mm | ||
| Shipping Dimensions (L*W*H) | 680*1050*400 mm | ||
| Machine Weight / N.W. | 88 kg | ||
| DISPLAY & COMMUNICATION | |||
| Display | LED+APP | ||
| Interface | RS485 / WiFi / CAN / DRM (Optional: Bluetooth / LAN / 4G / Meter) | ||